Ariston ABS VLS Flat 100 Technisch handboek - Pagina 8

Blader online of download pdf Technisch handboek voor {categorie_naam} Ariston ABS VLS Flat 100. Ariston ABS VLS Flat 100 18 pagina's. Storage electric water heaters

Ariston ABS VLS Flat 100 Technisch handboek

2.5 Power board, connections and probes

Sensor Test Table (ohmic resistance values as a function of temperature)
T [°C]
R [kΩ]
T [°C]
-40
195,7
-10
-35
148,2
-5
-30
113,3
0
-25
87,6
5
-20
68,2
10
-15
53,6
15
R [kΩ]
T [°C]
R [kΩ]
42,5
20
12,1
33,9
25
10,0
27,2
30
8,3
22,0
35
6,9
17,9
40
5,8
14,7
45
4,9
main power board (PCB)
power cable (PCB - HE1: red; PCB - HE2: blue)
HE1 probe with cable (width = 8 mm)
HE2 probe with connector (width = 6,5 mm)
HE2 probe cable
T [°C]
R [kΩ]
T [°C]
50
4,2
55
3,5
60
3,0
65
2,6
70
2,2
75
1,9
8
R [kΩ]
T [°C]
80
1,7
110
85
1,5
115
90
1,3
120
95
1,1
125
100
1,0
105
0,9
R [kΩ]
0,8
0,7
0,6
0,5