For example, this parameter setting is initially set to 240 which is the
delay time in 4 minutes or 240 seconds.You may set the value to
the desired Motion Sensor delay time to any amount of seconds as
you like. So if you want the time out to be 5 minutes after the Motion
Sensor is triggered, set this parameter to the value of 300.

Setting the sensitivity of your MultiSensor.

Parameter 6 [1 byte decimal] can be configured through your
gateway in case the default settings of your MultiSensor are not
what you desire.
For example, this parameter setting is initially set to 64 which is
the normal sensitivity, if you set it to 127, the sensitivity will be the
maximum sensitivity. If set it to 0, the sensitivity will be the minimum
sensitivity.

Monitoring temperature, humidity, luminance and ultraviolet.

Your MultiSensor can report temperature, humidity, luminance and
ultraviolet across a Z-Wave network when requested. If this function
is supported by a controller, generally a gateway, the data will be
displayed within its interface. The specific Z-Wave commands
for the support of monitoring is the Multilevel Sensor Command
Class. Automatic reports are sent to association group 1, which
is setup via the Association Command Class. Please consult the
controller's operation manual for specific instructions on setting your
MultiSensor.
14

For wall mounting using the Back-Mount Arm:

7