Aeotec AEOEZW116 Manual - Page 11

Browse online or download pdf Manual for Switch Aeotec AEOEZW116. Aeotec AEOEZW116 16 pages. Single nano switch with measuring
Also for Aeotec AEOEZW116: Quick Start Manual (11 pages)

Aeotec AEOEZW116 Manual
Parameter 90: Enables/disables parameter 91 and 92 below:
Enables/disables the function of parameter 91 and 92.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 91: Set the threshold value of wattage.
Threshold change in wattage (in terms of wattage) to induce an automatic report.
Size: 2 Byte, Default Value: 25
Setting
0 - 60000
Parameter 92: Set the threshold value of wattage.
Threshold change in wattage (in terms of percentage) to induce an automatic report.
Size: 1 Byte, Default Value: 5
Setting
0 - 100
Parameter 100: Set parameter 101-103 to default value.
Set parameter 101-103 to default value.
Size: 1 Byte, Default Value: 0
Setting
0
Parameter 101: To set which reports need to be sent in Report group 1.
To set which reports need to be sent in Report group 1.
Size: 4 Byte, Default Value: 0
Setting
1
2
4
8
Parameter 102: To set which reports need to be sent in Report group 2.
To set which reports need to be sent in Report group 2.
Size: 1 Byte, Default Value: 0
http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW116
Description
Disable
Enable
Description
The thershold value range is 0 to 60000
Description
The thershold value range is 0 to 100
Description
Reset the parameter 101-103
Description
Send Meter Report of voltage (V)
Send Meter Report of current (A)
Send Meter Report of wattage (W)
Send Meter Report of energy (kWh)
30-09-2020 13:25
Pagina 11 van 16