Aeotec AEOEZW116 매뉴얼 - 페이지 11
{카테고리_이름} Aeotec AEOEZW116에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aeotec AEOEZW116 16 페이지. Single nano switch with measuring
Aeotec AEOEZW116에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (11 페이지)
Parameter 90: Enables/disables parameter 91 and 92 below:
Enables/disables the function of parameter 91 and 92.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 91: Set the threshold value of wattage.
Threshold change in wattage (in terms of wattage) to induce an automatic report.
Size: 2 Byte, Default Value: 25
Setting
0 - 60000
Parameter 92: Set the threshold value of wattage.
Threshold change in wattage (in terms of percentage) to induce an automatic report.
Size: 1 Byte, Default Value: 5
Setting
0 - 100
Parameter 100: Set parameter 101-103 to default value.
Set parameter 101-103 to default value.
Size: 1 Byte, Default Value: 0
Setting
0
Parameter 101: To set which reports need to be sent in Report group 1.
To set which reports need to be sent in Report group 1.
Size: 4 Byte, Default Value: 0
Setting
1
2
4
8
Parameter 102: To set which reports need to be sent in Report group 2.
To set which reports need to be sent in Report group 2.
Size: 1 Byte, Default Value: 0
http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW116
Description
Disable
Enable
Description
The thershold value range is 0 to 60000
Description
The thershold value range is 0 to 100
Description
Reset the parameter 101-103
Description
Send Meter Report of voltage (V)
Send Meter Report of current (A)
Send Meter Report of wattage (W)
Send Meter Report of energy (kWh)
30-09-2020 13:25
Pagina 11 van 16