ACOM1000 TOP COVER REMOVAL and INSTALLATION
SAFETY FIRST!
W A R N I N G
HIGH VOLTAGE!
===========================
The amplifier works with high voltages up to
3000V
which
is LETHAL!
For your
safety pull the amplifier power plug out of the mains wall outlet and WAIT AT
LEAST 30minutes EACH TIME BEFORE you remove the cover of the amplifier.
Disconnect all cables from the amplifier (grounding last). Do not touch any
part inside while the amplifier is open because some residual voltages may
still be present!
1. Removing the top cover.
Using a Philips-2 screwdriver, unscrew 9 pcs of "eco-fix" flange-button head
screws to release the top cover (2x3 pcs on each bottom-side edge, and three
more on the rear-top edge of the box). Don't unscrew four screws that hold the
grid above the tube.
Lift the rear edge of the cover slightly (to 2-3cm) and then pull the cover
backwards, in order to release it from front-panel's chutes. Remove the top
cover.