Ariston ASL 65 VXS NA - 35140 Care, Use And Installation Booklet - Page 11

Browse online or download pdf Care, Use And Installation Booklet for Dryer Ariston ASL 65 VXS NA - 35140. Ariston ASL 65 VXS NA - 35140 40 pages. Tumble dryer

Installation Instructions
Read these instructions with care.
These instructions are provided for use by qualified
installers, in addition the installation must comply with:
In the United States, in accordance with the
National Electric Code ANSI/NFPA70 - latest edition
and any State, Municipal or local codes.
In Canada, in accordance with the Canadian
Electric Code C22.1 - latest edition and any
Provincial, Municipal or local codes.

Electrical

The dryer comes with a four-wire power supply cord
fitted with a 14-30P (plug), a receptacle should be
fitted in a location accessible after the dryer is
installed. The four wire dryer wire cord assembly fitted
must be used when the appliance is installed in a
location where grounding through the neutral is
prohibited. Grounding through the neutral is prohibited
for; new branch-circuit installations; mobile homes,
recreational vehicles and areas were local codes do
not allow grounding through the neutral conductor.
If a 10-30R (receptacle) is installed a locally obtained
3 wire dryer cord kit minimum ratings 240V, 30A, 90C
and marked for clothes dryers (ring terminals) should
be fitted
To fit a 10-30P dryer cord assembly follow the steps
below:
1. Make sure the dryer is not plugged into a power
outlet.
2. Remove the cover from the cable junction box
located on the rear of the dryer.
3. Remove Green link wire from ground terminal.
4. Loosen the nut securing the cable bush, disconnect
and discard the existing cable and bush.
5. Fit one end of the Green link to the ground terminal
using washer and nut. Position the link wire to the
Neutral terminal (N), but do not fit securing screw at
this stage.
Green link wire.
6. Follow any instructions provided with the kit and fit
the cable using the strain relief supplied with the
kit, do not fully tighten the strain relief at this stage.
www.aristonappliances.us
7. Connect the L1, N and L2 wires.
On flat cords the center wire is the Neutral conductor,
fit to the terminal marked 'N'. On round cords the
Green or White conductor should be fitted to the
terminal marked 'N'.
8. Fully tighten the terminal block screws and ground
connection nut, position the cord, finally fully tighten
the strain relief.
9. Refit the cover to the box.
Grounding
Some local codes may require a separate ground. In
such cases the required ground wire, clamp and
screw must be purchased separately.
NEVER ground the dryer to plastic plumbing lines,
gas lines or water pipes.
NOTE: IF IN DOUBT ABOUT ANY OF THE ABOVE
CONSULT A QUALIFIED ELECTRICIAN.

Where to put your dryer

Check local codes before choosing a location. Some
codes do not permit installation in a garage, closet,
mobile home or bedroom.
DO NOT install the dryer in an area where gasoline or
other inflammable materials are kept or stored.
When operating the dryer, there has to be adequate
ventilation to avoid the back flow of gases into the
room from appliances burning other fuels, including
open fires.
Minimum installation clearances:
Closet
Sides
/
" (15mm)
3
4
Top
/
" (10mm)
1
2
Rear
/
" (15mm)
3
4
Front
/
" (15mm)
3
4
If installed in a closet it must have the following
dimensions and have two ventilation openings each
having an area 72 sq.ins. (450 sq.cm) located 6"
(150mm) from top and bottom of the door. It must
NEVER be installed in a closet with a solid door.
The dryer has adjustable height feet, use these to
level the dryer after fitting into its final position.
Under counter
/
" (15mm)
3
4
/
" (10mm)
1
2
/
" (15mm)
3
4
not applicable
11
EN