Whirlpool LI3YRB Installation Instructions And Use & Care Manual - Page 7
Browse online or download pdf Installation Instructions And Use & Care Manual for Ventilation Hood Whirlpool LI3YRB. Whirlpool LI3YRB 28 pages. 36" (91.4 cm) island-mount canopy range hood
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the ceiling where the
range hood will be installed, considering the requirements for
ceiling support structures. See the "Location Requirements"
section. Make sure the range hood is centered over the
cooking surface.
2. Tape template in place on the ceiling at the marked
centerline. The line for the front of the range hood should be
parallel to the front of the cooktop.
3. Use a pencil to mark the mounting screws, wire access and
duct hole locations on the ceiling.
NOTE: Mounting hole locations should be into a ceiling
support structure capable of holding 80 lbs (36.6 kg).
Remove the template.
4. Drill 4 - ³⁄₁₆" (4.8 mm) pilot holes for mounting the upper
horizontal support.
Complete Preparation
1. Determine the required location for the home power supply
cable and drill a ½" (1.3 cm) diameter hole for wire access.
2. Run ½" (1.3 cm) conduit and wires or home power supply
cable according to the National Electrical Code or CSA
Standards and local codes and ordinances. There must be
enough ½" conduit and wires or home power supply cable
from the fused disconnect (or circuit breaker) box to make the
connection in the hood's electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
3. For vented installations only: Using a jigsaw or keyhole
saw, cut a 6½" (16.5 cm) diameter hole for the vent duct.
4. Attach the upper horizontal support bracket with 4 - 5 x
45 mm wood screws.
NOTE: Upper horizontal support screws must be into a
ceiling support structure capable of holding 80 lbs (36.6 kg).
A
A. Upper horizontal support
Assemble Range Hood
1. Assemble rubber seals to the front and back flange of the
ventilator assembly.
A. Rubber seal
2. Assemble and center glass canopy to ventilator assembly.
NOTE: The range hood should be sitting on covered spacers
for assembling the glass canopy to the ventilator assembly.
A
A. Covered spacers
B. Glass canopy
C. Ventilator assembly
3. Install retainer bracket to both sides and secure with 4 - 4 x
8 mm screws to hold glass canopy to ventilator assembly.
A
B
A. Retainer bracket
B. Glass canopy
C. Ventilator assembly
4. Position the 4 vertical supports (A) with the notches at the
bottom and attach to the range hood using 16 - 4 x 8 mm
screws.
A
C
B
C
7