TROUBLE
SHOOTING
PROCEDURE
lf entire
unit is not working,
proceed
as follows:
1.
Check
circuit
breaker
box to insure
that breaker
for hood is not tripped.
2.
Remove
printed
circuit
board enclosure
cover
by removing
two screws
securing
the cover.
(See Figure
I .)
CAUTION:
SHOCK
HAZARD
SOME CIRCUIT
BOARD COMPONENTS
(INCLUDING
HEAT SINKS) ARE NOT ISOLATED
FROM
THE AC POWER LINE.
3.
Disengage
five pin connector
from P. C. board
and check
for 115VAC
(nominal)
AC line voltage
between
the black
wire socket
(end socket)
and white
wire socket
(center
socket)
by inserting
VOM probes
into sockets.
4.
If voltage
is not present,
proceed
as follows:
a.
Turn off power
at breaker
box.
b.
Check
connections
in rear power
entry
box. (See Fig. 1.)
(1) Push in filter
retainmg
tabs and remove
filter from wiring
compartment.
(2) Remove
cover
retaining
screws
and cover.
(3) Remove
wiring
box covers
(2).
C.
Check
continuity
of wires
from wire nut connections
to P. C. board sockets
by inserting
one
meter probe
in wire nut connection
and the other
probe
in respective
socket
connector.
d.
Repair
or replace
as required,
restore
power
to unit and again check
for voltage
at P. C. board
connector.
5.
If the fan or light still does not operate,
proceed
as follows:
a.
With five pin connector
plugged
into board and light and/or
fan turned
on, check output
of the
red (light)
and blue (fan) wires
in the five pin connector
by inserting
one probe of the meter in
the backof
thesocket
at therespectivewireconnection
(redor
blue) andtheotherprobein
the
back of the socket
at the black wire connection.
(1)
Reading
for red wire output
should
be 50-65 VAC if the light is on "Lo" or loo-125
VAC if
the light is on "Hi".
(2)
Reading
for blue wire output
should
be between
72 VAC and the line voltage
reading,
depending
upon fan speed setting.
b.
If output
readings
are correct,
problem
is in the wiring
from plug to devices
(fan and light) or in
the devices
themselves.
(Bad socket
or bulb and/or
defective
fan motor.)
C.
If outputs
are not correct,
problem
is in the circuit
board or membrane
switch.
(See Page 2.)
CIRCUIT