Install Vent Covers

NOTE: Remove protective film from the vent covers.
1. When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with (2) 2.9 x 6.5 mm screws.
D
C
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
NOTE: For vented installations, the upper vent cover
may be reversed to hide slots.
The range hood is designed to remove smoke, cooking
vapors, and odors from the cooktop area. For best results,
start the hood before cooking and allow it to operate several
minutes after the cooking is complete to clear all smoke and
odors from the kitchen. The hood controls are located on the
front side of the canopy.
A. Grease filter
B. Grease filter handle
C. Blower and light controls
D. LED lights
10
C
A
B

RANGE HOOD USE

Complete Installation

1. For non-vented (recirculating) installations only, install
charcoal filters over the grease filters, using the clips
provided in the kit. See the "Range Hood Care" section.
2. Install metal filters. See the "Range Hood Care" section.
3. Check the operation of the range hood blower and light.
See the "Range Hood Use" section.
NOTE: To get the most efficient use from your new range
hood, read the "Range Hood Use" section.

Range Hood Controls

A
B
A. Light button
B. Blower ON/OFF and minimum speed button
C. Blower speed medium button
D. Blower speed maximum button
Operating the light
The
button controls both lights. Press once for ON and again
for OFF.
Operating the blower
The ON/OFF button turn the blower on and set the blower
minimumspeed and sound level for quiet operation. The speed
can be changed anytime during fan operation by pressing the
desired Blower Speed button.
Press the blower ON/OFF button a second time to turn the
blower off.
C
D