Power supply – eControl INSTAHEAT Hob
● WARNING: THIS APPLIANCE MUST BE EARTHED.
● THIS APPLIANCE IS SPECIFICALLY DESIGNED FOR THE VOLTAGE STATED
A 1PH 40amp 230V fused power supply is required near the appliance (when paired with a 2, 3 or 4 oven Series X
eControl System). External wiring to the unit must be installed using the supplied mains cable in accordance with
current wiring regulations and any applicable local regulations. If the cable is cut, new ferrules must be installed on
the stripped conductors.
The method of connecting to the mains electricity supply must allow for complete electrical isolation of the appliance
by using a multi-pole switch with at least 3mm contact separation on all poles.
The method of connecting to the mains electricity supply must allow for complete electrical isolation of the
appliance.
The isolator should not be installed directly above the cooker, but rather within 2 metres of it.
The isolator and the connection point may be separate.
The INSTAHEAT hob is rated at 2.5kw/hr.
Installation Procedure
The eControl INSTAHEAT hob is provided as a sealed and pre-assembled unit.
This appliance should only be installed by an eControl trained engineer under strict accordance to the installation
instructions. The hob is only compatible with the Series X eControl box it is supplied with and not compatible as a
retro-fit product on any other eControl System.
Unpack the INSTAHEAT hob and check for any signs of damage.
Fit the RHS HOB limiting thermostat capillary into the 2 x U clips to the underside of the radiant heating element and
secure. Ensure the capillary is housed correctly, do not overtighten.
Lower the hob unit into the RIGHT HAND SIDE hob aperture on the cooker top plate whilst feeding the braided
connection lead into the cooker void at the 9 o'clock position.
Centralize the pre-assembled chassis onto the aperture and apply a layer of black high temperature silicone
(provided) to seal between chassis and top plate.
Fit the 5mm round section silicone cord into the bed of silicone and butt joint at the 12 o'clock position. Wipe any
excess residue with a damp cloth and dry.
Connect the element into the rear of the eControl box using the male plug provided. Earth onto the earthing post on
the rear of the eControl box.
TEST THE INSTAHEAT HOB AT THE POINT OF INSTALLATION BUT TO DO NOT LEAVE ON FOR AN EXTENDED PERIOD
UNTIL A MINIMUM OF 8 HOURS CURING TIME IN RESPECT OF THE HIGH TEMPERTURE SILICONE SEALANT.