ELECTRICAL CONNECTIONS (110V ONLY)
WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO A
POWER SUPPLY.
This product can be connected to one of the following power supplies:
• 110V Generator, 110V Isolating Transformer or 110V Site supply
Connecting it to any other power source may
cause damage.
This product includes a fitted industrial plug to BS-
EN 60309, and a cable for use with a 110 volt
supply.
ON NO ACCOUNT MUST A 230V, 13AMP (BS1363)
PLUG BE USED.
If using a portable 110V transformer make sure it
has a rated capacity sufficient to take the load of
the saw.
If the plug needs changing at any time, a plug of
identical specification must be used:
1. Undo the socket screws & remove the rear
section.
2. Rotate the cable clamp clear of the terminals.
3. Feed the cable through the rear gland in the
plug.
4. Remove the cable sheath to the required lengths as shown in the diagram.
5. Terminate the correct wires in the
correct terminal blocks as shown.
6. Remove the cable clamp screws. Clip
the cable clamp back into position and
place the clamp around the outer
sheath of the cable. Replace the screws
and tighten until the cable is secure.
7. Replace the rear cover and tighten the
cover screws.
If in any doubt, consult a qualified electrician. DO NOT attempt any repairs
yourself.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]