ArmorAll AA256 Operator's Manual - Page 11
Browse online or download pdf Operator's Manual for Vacuum Cleaner ArmorAll AA256. ArmorAll AA256 12 pages. 2.5 gal / 9.4 l wet/dry vacuums
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam sleeve filter. (fig. 4)
2. Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water. (fig 5.)
3. Allow filter to air dry before installing and using again.
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING
Symptom
Vacuum will not operate
Dust comes from motor cover.
Reduced efficiency and
motor/speed vibration.
TROUBLESHOOTING
Possible Causes
1) No power supply.
2) Faulty power cord.
3) Container full.
1) The reusable cloth filter is missing
or damaged.
1) There is a blockage in the nozzle,
hose, or the vacuum inlets. Or the
dust filter is blocked by fine dust.
Corrective Action
1) Check power supply – cord,
breakers, fuses.
2) Unplug and check the power
cord. If damaged, have it repaired
by a professional.
3) Empty container.
1) Attach or replace the reusable
cloth filter.
1) Check nozzle, hose and inlets
for blockage. Take off the filter and
clean it. Or install new filter.
11