ArmorAll AA256 Руководство по эксплуатации - Страница 11

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Пылесос ArmorAll AA256. ArmorAll AA256 12 страниц. 2.5 gal / 9.4 l wet/dry vacuums

ArmorAll AA256 Руководство по эксплуатации
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam sleeve filter. (fig. 4)
2. Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water. (fig 5.)
3. Allow filter to air dry before installing and using again.
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING
Symptom
Vacuum will not operate
Dust comes from motor cover.
Reduced efficiency and
motor/speed vibration.

TROUBLESHOOTING

Possible Causes
1) No power supply.
2) Faulty power cord.
3) Container full.
1) The reusable cloth filter is missing
or damaged.
1) There is a blockage in the nozzle,
hose, or the vacuum inlets. Or the
dust filter is blocked by fine dust.
Corrective Action
1) Check power supply – cord,
breakers, fuses.
2) Unplug and check the power
cord. If damaged, have it repaired
by a professional.
3) Empty container.
1) Attach or replace the reusable
cloth filter.
1) Check nozzle, hose and inlets
for blockage. Take off the filter and
clean it. Or install new filter.
11