Blagdon Powersafe Series Quick Start Manual - Page 5
Browse online or download pdf Quick Start Manual for Switch Blagdon Powersafe Series. Blagdon Powersafe Series 8 pages. Power switch box 2/3/4/5 way
1.
Prepare the cable (see cable preparation diagram - inside front cover).
A maximum external cable diameter of 9mm is permitted.
IMPORTANT:
Please note that the mains input must be connected to the green power input
cable block only.
Switch one has a maximum loading of 1000w 1.0KW.
Switch two and subsequent switches are rated to a maximum wattage of 300w 0.3 KW.
These ratings must not be exceeded by the maximum wattage stated on the appliance to be
fitted to each switch.
2.
Remove the cable gland cover and thread it over the cable of the appliance to be fitted.
(see gland detail diagram on colour Switch box wiring diagram - inside front cover).
Note: The cable glands have a plug that should be retained if the gland is not being
used for a application. This should be inserted to maintain a weatherproof seal.
INSTALLATION
Circuit Board Removal
Remove the circuit board by
unscrewing the locating screw
and wire each appliance
before replacing and locating
into the box.
5