READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
EXCESSIVE AIR PRESSURE
STATIC SPARK
WARNING EXCESSIVE AIR PRESSURE. Can cause person
al injury, pump damage or property damage.
S
Do not exceed the maximum inlet air pressure as stated on the
pump model plate.
S
Be sure material hoses and other components are able to with
stand fluid pressures developed by this pump. Check all
hoses for damage or wear. Be certain dispensing device is
clean and in proper working condition.
WARNING STATIC SPARK. Can cause explosion resulting
in severe injury or death. Ground pump and pumping system.
S
PD02P XDS DTX Groundable Acetal pumps: Use the pump
grounding screw provided. A screw terminal is provided on
the manifold. Connect a 12 ga. (min.) wire (66885 1 kit is avail
able) to a good earth ground source.
S
The pumping system and object being sprayed must be
grounded when it is pumping, flushing, recirculating or spray
ing flammable materials such as paints, solvents, lacquers,
etc. or used in a location where surrounding atmosphere is
conducive to spontaneous combustion.
S
Use the pump grounding screw terminal provided. Use Aro
Part No. 66885 1 Ground Kit or connect a suitable ground wire
(12 ga. min.) to a good earth ground source.
S
Secure pump, connections and all contact points to avoid
vibration and generation of contact or static spark.
S
Consult local building codes and electrical codes for specific
grounding requirements.
S
After grounding, periodically verify continuity of electrical
path to ground. Test with an ohmmeter from each component
(e.g., hoses, pump, clamps, container, spray gun, etc.) to
ground to insure continuity. Ohmmeter should show 100
ohms or less.
S
Submerse the outlet hose end, dispensing valve or device in
the material being dispensed if possible. (Avoid free stream
ing of material being dispensed.)
S
Use hoses incorporating a static wire.
S
Use proper ventilation.
S
Keep inflammables away from heat, open flames and sparks.
S
Keep containers closed when not in use.
WARNING Pump exhaust may contain contaminants. Can
cause severe injury. Pipe exhaust away from work area and
personnel.
S
In the event of a diaphragm rupture material can be forced out
of the air exhaust muffler.
S
Pipe the exhaust to a safe remote location when pumping haz
ardous or inflammable materials.
S
Use a grounded 1/4" min. i.d. hose between the pump and the
muffler.
WARNING HAZARDOUS PRESSURE. Can result in serious
injury or property damage. Do not service or clean pump,
hoses or dispensing valve while the system is pressurized.
PAGE 2 OF 8

OPERATING AND SAFETY PRECAUTIONS

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE
S
Disconnect air supply line and relieve pressure from the sys
tem by opening dispensing valve or device and / or carefully
and slowly loosening and removing outlet hose or piping from
pump.
WARNING HAZARDOUS MATERIALS. Can cause serious
injury or property damage. Do not attempt to return a pump to
the factory or service center that contains hazardous material.
Safe handling practices must comply with local and national
laws and safety code requirements.
S
Obtain Material Safety Data Sheets on all materials from the
supplier for proper handling instructions.
CAUTION Verify the chemical compatibility of the pump
wetted parts and the substance being pumped, flushed or re
circulated. Chemical compatibility may change with tempera
ture and concentration of the chemical(s) within the
substances being pumped, flushed or circulated. For specific
fluid compatibility, consult the chemical manufacturer.
CAUTION Maximum temperatures are based on mechani
cal stress only. Certain chemicals will significantly reduce
maximum safe operating temperature. Consult the chemical
manufacturer for chemical compatibility and temperature lim
its. Refer to PUMP DATA on page 1 of this manual.
CAUTION Be certain all operators of this equipment have
been trained for safe working practices, understand it's limita
tions, and wear safety goggles / equipment when required.
CAUTION Do not use the pump for the structural support of
the piping system. Be certain the system components are
properly supported to prevent stress on the pump parts.
S
Suction and discharge connections should be flexible con
nections (such as hose), not rigid piped, and should be com
patible with the substance being pumped.
CAUTION Prevent unnecessary damage to the pump. Do
not allow pump to operate when out of material for long peri
ods of time.
S
Disconnect air line from pump when system sits idle for long
periods of time.
CAUTION Use only genuine ARO replacement parts to as
sure compatible pressure rating and longest service life.
Replacement warning labels are available upon
NOTICE
request: ``Static Spark & Diaphragm Rupture'' PN \ 94080.
= Hazards or unsafe practices which could
WARNING
result in severe personal injury, death or
substantial property damage.
= Hazards or unsafe practices which could
CAUTION
result in minor personal injury, product
or property damage.
= Important installation, operation or
NOTICE
maintenance information.
PD02P X