AIR AND LUBE REQUIREMENTS
WARNING EXCESSIVE AIR PRESSURE. Can cause pump
damage, personal injury or property damage.
S
A filter capable of filtering out particles larger than 50 microns
should be used on the air supply. In most applications there is no
lubrication required other than the O" ring lubricant which is ap
plied during assembly or repair.
S
The pump can be rotated 360_ to suit the application. It may be
mounted upside down or on the wall with no effect on suction lift or
operating efficiency. The filter and regulator need to be oriented in a
normal vertical direction to function properly.
S
Pipe plugs are included for the material inlets. They can be
switched to accommodate piping requirements. However, the fluid
inlet must always be in the port closest to the mounting base.
S
When lubricated air is necessary, supply the air lubricator with a
good grade of SAE 90 wt. non detergent oil and set the lubricator to
a rate not to exceed one drop per minute.
INSTALLATION
S
NOTICE: Re torque fasteners prior to use. Refer to step #18 on
page 6 for information.
S
Apply Teflon tape or pipe sealant to threads upon assembly to pre
vent leakage.
S
Secure the diaphragm pump legs to a suitable surface to insure
against damage by vibration.
S
To avoid problems, install a particle fluid filter to screen out foreign
matter 1/32" (.79 mm) or larger in diameter.
S
The pump is not recommended for submerged applications.
S
When the diaphragm pump is used in a forced feed (flooded inlet)
situation, it is recommended that a Check Valve" be installed at the
air inlet.
S SantopreneR is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. S LubriplateR is a registered trademark of Lubriplate Division (Fiske Brothers)
PD02P X
S TeflonR is a registered trademark of the DuPont Company, S KynarR is a trademark of Penwalt Corp.,
OPERATING INSTRUCTIONS
S
Always flush the pump with a solvent compatible with the material
being pumped, if the material being pumped is subject to ``setting
up" when not in use for a period of time.
S
Disconnect the air supply from the pump if it is to be inactive for a
few hours.
S
The outlet material volume is governed not only by the air supply,
but also by the material supply available at the inlet. The material
supply tubing should not be too small or restrictive. Be sure not to
use hose which might collapse.
MAINTENANCE
Refer to the part list on page 4 for Service Kit Information, parts view on
page 5 and Repair Procedures on page 6.
S
Certain ARO Smart Parts" are indicated which should be available
for fast repair and reduction of down time.
S
Service kits are divided to service two separate diaphragm pump
functions: 1. Air Section, 2. Fluid Section. The Fluid Section is di
vided further to match typical part Material Options.
S
Provide a clean work surface to protect sensitive internal moving
parts from contamination from dirt and foreign matter during ser
vice disassembly and reassembly.
S
Keep good records of service activity and include pump in preven
tive maintenance program.