CAME Z Series Installation Manual - Page 7

Browse online or download pdf Installation Manual for Control Panel CAME Z Series. CAME Z Series 11 pages. Control board
Also for CAME Z Series: Manual (8 pages), Manual (20 pages), Manual (4 pages), Manual (4 pages), Manual (17 pages), Manual (17 pages), Manual (13 pages), Manual (13 pages), Manual (16 pages), Manual (16 pages), Manual (12 pages), Manual (12 pages), Manual (18 pages), Manual (8 pages), Manual (20 pages), Manual (12 pages), Manual (12 pages), Technical Documentation Manual (16 pages), Instructions Manual (16 pages), Instructions (4 pages), Quick Manual (2 pages), Connection Manual (4 pages), Manual (4 pages), Manual (12 pages), Manual (20 pages), Manual (15 pages), Instruction Manual (12 pages), Quick Start Manual (12 pages), Manual (16 pages)

CAME Z Series Installation Manual
(N.C. Contact for "re-opening during closing" - Input for photocells, sensiti-
ve profi les and other devices complying with EN 12978 standards.
During the closing phase, operating the device will invert the motion until
complete opening is achieved.
If this contact is not used, bridge the terminals amongst themselves.
(N.C.) Contact for "re-closing during opening" – Input for photocells, sensiti-
ve edges and other devices compliant with EN 12978 standards.
During opening, operation of the device causes inversion of direction until
complete closure is obtained.
If this contact is not used, bridge the terminals amongst themselves.
(N.C.) Contact for "partial stop" – Input for photocells, sensitive edges and
other devices complying with the EN 12978 standard. Stops the gate leaf if it
is moving and, if set up, automatically closes the gate.
If this contact is not used bridge the terminals amongst themselves.
Connection for the 12V electric-lock – 15W max.
(N.O.) contact output – the contact shuts off for 3" with
each opening-impulse.
Contact rate: 2A – 230V A.C.
(N.O.) Contact output with two-channel receiver
Contact rate (with resistive load): 1A – 24V D.C.
7