CAME v6000 Installation Manual - Page 12

Browse online or download pdf Installation Manual for Garage Door Opener CAME v6000. CAME v6000 17 pages. For garage doors

CAME v6000 Installation Manual

Optional functions

Setting the alarm

By default, the function is deactivated; when the
alarm is active the operator will emit a beep if the
door remains open for more than 10 minutes. To
activate it:
Press P for about 5 sec-
onds, 1 appears.
”
Press + and select 6
Press P, 0 appears.
Press + and select 1. The
alarm is now active.
Press P to save the setting.
The last phase of programming is always
storage (function 5), otherwise the settings are not
saved.
Manoeuvre counter
By default, the function is disabled.
When this function is activated, after 2,000 cycles,
the operator beeps in indication of maintenance
required.
To turn off the sound, disconnect and reconnect the power.
To activate:
Press P for about 5 sec-
onds, 1 appears.
”
Press + and select 8.
Press P, 0 appears.
Press +, 1 appears: the
function is active.
Press P to save the
operation.
The last phase of programming is always
storage (function 5), otherwise the settings are not
saved.
Adjusting the automatic closing intervention time;
By default, the function is disabled. To activate it:
Press P for about 5 sec-
onds, 1 appears.
”
Press +
and select 7.
Press P, 0 appears.
Press + and select 1.
Automatic closing is
activated and the standby
time is 30 seconds.
To change standby time before closing, press + or -.
60 seconds
180 seconds
Press P to save the
operation.
The last phase of programming is always storage (function 5), otherwise the settings are not saved.
The operator emits a sound for 20 seconds before the door starts to close automatically. At the same time, the
courtesy light fl ashes. When the door starts to close, the operator emits a sound and the courtesy light remains on
steadily. With the door closed, the operator does not emit any sound and the courtesy light stays on for 3 minutes.
Automatic Closing Warning Function
By default, the function is active.
With function enabled, the operator emits a sound
for 20 seconds before starting automatic closing.
To disable, proceed as follows:
Press P for about 5 sec-
onds, 1 appears.
”
Press + and select 9
Press P, 1 appears.
Press -, 0 appears: the
function is disabled.
Press P to save the setting.
The last phase of programming is always
storage (function 5), otherwise the settings are not
saved.
90 seconds
120 seconds
210 seconds
240 seconds
150 seconds