Setting a DMX Address via RDM

Gallery Series LED Luminaires are full featured Remote Device Management (RDM) compliant. All DMX
and Luminaire settings are programmed via a RDM ANSI E1.20 complaint device. As many of the RDM
devices and software work differently please consult the RDM programmer manufacturer for specific
operational instructions. Table 6 on page 18 shows the list of the settings and features that can be set via
RDM.
Note: The entire DMX infrastructure must be RDM compliant in order to achieve system-wide
RDM functionality.
RDM Protocol Version
DMX 512 Start Address
Item
Device Model ID
Product Category
Boot Version
Software Version ID
DMX Foot Print
Manufacturer Label
Dimming Curve
Value
0100
LED Driver 40W
Specialized LED Dimmer
0.00
V000001.12
1 (default)
1 (default)
Altman
Linear (default)
Table 6: DMX Addressing