16.1. Filter replacement

Always use protective gloves and respiratory protection when handling used filters! Risk of ill health and sickness.
1.
Switch off the Air Cleaner Concealed by turning
the safety switch or electrical connector. Make
sure that the green operating led is off.
2.
Undo the two knobs from the top cover and
remove it. NB! Hold the top cover firmly.
Alternatively, secure it during removal.
3.
Grip the upper edge of the bag filter frame pull
it towards you. And put the filter into a plastic
bag.
4.
Release the screw (counter clock wise) which
keeps the HEPA filter in place.
Air Cleaner Consealed CC400 manual,
TECHNICAL MANUAL
Air Cleaner CC400 Concealed
5.
Take a firm grip the sling which is around the
HEPA filter and pull it towards you.
6.
Lift the filter carefully out. Scrapped filters must
be taken care of as per the previously
explained instructions. Do the steps 1-6 in
reverse order.
Take a new HEPA filter out of its box. NB!
Do not touch the filter's surface. Hold the
frame only!
Do the steps 1- 8 in reverse order.
Ver. 001