Alula RE210T Install Manual - Page 2
Browse online or download pdf Install Manual for Security Sensors Alula RE210T. Alula RE210T 4 pages. Indoor motion sensor-pet immune 2gig compatible
Install
using the included 3M VHB
sensor on a wall or in a corner. The tape should be applied
to the back when wall mounting or to the back bevels when
corner mounting. Alternatively, screw mounting can be done
by punching out the screw mounting holes.
Installation Tips
• Mount 7.5 to 9.5 feet from the floor for an optimal
balance between catch performance and pet
immunity.
• Remove the cover and circuit board before trying
to punch out the screw mounting holes.
• Ensure the bug foam stays intact and snug around
the IR sensing element when re-installing the
circuit board.
External Contact (not evaluated by ETL)
• Use a normally-closed contact because the motion sensor will transmit an
alarm when it sees the external contact open.
• Do not use end-of-line resistors.
Pro Tips
Walk test mode is entered by pressing the motion
sensor's tamper button. The walk test lasts three
minutes.
Walk Test Operation
• The walk test LED turns on when motion
is sensed.
• The motion sensor performs a
re-calibration after each activation. The
re-calibration takes about 30 seconds.
The sensor will NOT sense motion
during the re-calibration.
• Wireless transmissions are sent for each
detection, so walk test mode can also
be used to test the panel.
3M VHB tape works great if the surface is properly
prepared and firm pressure is applied for over 10
seconds.
Surface Preparation
• Clean the surface
• Ensure the mounting surface
temperature is above 50 °F
Motion lockout is active for three minutes after a motion event is detected. During the
motion lockout period, motion events will be ignored.
Motion sensitivity can be adjusted by the sensitivity jumper on the circuit board.
• Jumper Installed (lower sensitivity): Detects person in 3 to 5 steps.
Increases pet immunity. Usually for security applications.
• Jumper NOT Installed (higher sensitivity): Detects person in 2 to 4 steps.
Usually for occupancy applications.
tape to adhere the motion
®
Mounting Screw Holes
Walk Test LED
Cover Tamper Switch
Bug Foam IR Sensing Element
Low - Jumper ON
High - Jumper OFF
Battery
External Contact
Sensitivity