AKO 14801 Instructions
Browse online or download pdf Instructions for Controller AKO 14801. AKO 14801 2 pages. Surface differential controller, 230 v, 2 relays
GB
1480H102 Ed.03
Surface differential controller, 230 V, 2 relays
Thermostat designed to display, control and regulate thermal solar energy applications
in domestic hot water facilities.
1- Versions and references
MODEL
FUNCTION
16 A, 250 V, cos j
AKO-14801
Controller
R2 (Fan / Support Resistanceo):
8 A, 250 V, cos j
2- Technical data
Temperature range according to type of sensor configured:
NTC ..............................................................-50.0 ºC to 99.9 ºC (-58.0 ºF to 211 ºF)
PTC................................................................-50.0 ºC to 150 ºC (-58.0 ºF to 302 ºF)
Resolution, Set Point and differential:.............0,1 or 1 ºC/ºF configurable by parameter P7
Input for probe:
NTC ...................................................................................................AKO-149XX
PTC..................................................................................................AKO-1558XX
Thermometric accuracy: .......................................................................................± 1 ºC
Probe tolerance at 25 ºC:
NTC ...........................................................................................................± 0,4 ºC
PTC .........................................................................................................± 1.25 ºC
Maximum input power: ..........................................................................................5 VA
Working ambient temperature: ...................................................................5 ºC to 50 ºC
Storage ambient temperature: .................................................................-30 ºC to 70 ºC
Control device classification:
Independent mounting, with characteristic of automatic operation Type 1.B action, to
be used in a clean situation, logical medium (software) class A and continuous operation.
Degree of contamination 2 on UNE-EN 60730-1
Double insulation between the power supply, the secondary circuit and the relay output.
Allocated pulse temperature: ..............................................................................2500 V
Pressure ball test temperature:
Accessible parts:...................................................................................................75 ºC
Parts that position active elements:......................................................................125 ºC
Voltage and current declared by the EMC tests:............................................207 V, 21 mA
Current of radio jamming supression test: ...........................................................270 mA
3- Installation
The controller should be installed in a place protected from vibrations, water and corrosive
gases, and where ambient temperature does not surpass the value specified in the
technical data.
In order to give a correct reading, the probe should be installed in a place without heat
influences other than the temperature that is to be measured or controlled
3.1 Fastening:
Press gently to open the cover
Fixing holes for universal
flush-mounted box
S1
1
SONDAS
3.2 Connection:
PROBES
S2
2
The probe and its lead should NEVER be installed in ducting
3
along with power, control or power supply wiring.
The power supply circuit should be connected with a
minimum 2 A, 230 V, switch located close to the unit. Power
230V~
8
supply cables should be H05VV-F 2x0,5 mm or
10% 50/60Hz
±
9
In = 21mA~
H05V-K 2x0,5 mm .
*16A
R1
10
Section of connecting wires for relays contacts should be
*I max=16A
C
2
11
2,5 mm .
*8A
cosϕ=1 250V
R2
12
13
4- Front panel functions
F
LED (Pump R1)
Permanent: Pump Relay 1 energised.
X
LED (Fan R2 if P0=0)
Permanent: Fan Relay 2 energised.
RELAY
POWER SUPPLY, 50/60 Hz
R1 (Pump):
=1 SPST
230 V~ ±10%
=1 SPDT
Detail of fixin holes
Max. Ø 3,7
35
125,5
171
2
LED (Support Resistances R2 if P0=1)
Permanent: Support Resistances Relay
2 energised.
(
LED Alarm
Permanent: Alarm indicator enabled.
Flashing: Alarm detected, but display maintained.
LED ºC
Permanent: Degrees ºC indicator.
Flashing: Programming phase..
LED ºF
Permanent: Degrees ºF indicator.
Flashing: Programming phase.
N
UP key
- Press once to cancel the alarms, but they remain
displayed.
- Press to display the value of the second probe for
five seconds.
- In programming, it makes the displayed value
increase.
Q
DOWN key
- Press once to cancel the alarms, but they remain
displayed.
- In programming, it makes the displayed value
reduce.
- In the test mode it manually enables/ disables the
two relays R1 and R2. Display shows tSt.
O
RIGHT key
- Press once to cancel the alarms, but they remain
displayed.
- In programming, it makes the level value increase.
- In the test mode it manually enables/ disables the
R1 relay . Display shows tSt.
5- Adjustment and configuration
It should only be programmed or modified by personnel who are fully conversant with the
equipment operation and possibilities.
5.1 Set Point temperature
The factory SOLAR SET POINT default value is 2.0 ºC.
- Press SET key for at least 5 seconds to DISPLAY SOLAR SET POINT. The display shows SP1 for five
seconds. It displays the CURRENT SET POINT value and LED ºC or ºF starts flashing.
N
Q
- Press
or
keys to CHANGE SET POINT into the required value.
- Press SET key to ACCEPT THE NEW SET POINT. The display returns to the CURRENT
TEMPERATURE display status and LED ºC or ºF stops flashing.
P
- Press the
key to exit the temperature set point without modifying the value.
When PA is displayed, PASSWORD programmed in L5 parameter of tid menu should be entered
to access the CURRENT SET POINT.
O
- Press
key. 0 will be displayed to ENTER PASSWORD.
N
Q
- Press
or
keys to CHANGE NUMBER and DISPLAY PASSWORD programmed.
- Press SET key to ACCEPT PASSWORD. The CURRENT SET POINT value will be displayed and it
can be already modified.
5 Sec.
CURRENT
PASSWORD
TEMPERATURE
REQUEST
5.2 Parameters configurations
2
Level 1 Menus
N
Q
- When the keys
+
are pressed simultaneously for at least 10 seconds, the display
shows Pro for 10 seconds. LED ºC or ºF will be flashing, we are in the programming LEVEL
1 MENUS and the first menu "r1" is displayed.
N
- Press
key to access the next menu and
P
- Pressing
key, the controller returns to the CURRENT TEMPERATURE display status and
LED ºC or ºF will stop flashing.
k
When PA is displayed, PASSWORD programmed in L5 of "tid" menu should be entered to
access programming LEVEL 1 MENUS.
O
- Press
key. 0 will be displayed to ENTER PASSWORD.
N
Q
- Press
or
keys to CHANGE NUMBER and DISPLAY PASSWORD programmed.
- Press SET key to ACCEPT PASSWORD. The first menu "r1" will be displayed.
ºC
LED
Fan
ºF
LED
Alarm
LEFT
key
DOWN
key
P
LEFT key
- Press once to cancel the alarms, but they
remain displayed.
- Exit programming level.
- In the test mode it manually enables/
disables R2 relay. Display shows tSt.
SET key
- Press once to cancel the alarms, but they
remain displayed.
- In programming, accept the programmed
new value.
- When pressed it displays the help message
SP1 corresponding to the function
performed by the key.
- When pressed for at least 5 seconds, the
Solar Set Point temperature (SP1) is
displayed.
If P2=0 or L5=0
ENTER
DISPLAY
CURRENT
PASSWORD
PASSWORD
SET POINT
SET POINT
Q
key to return to previous one.
LED ºC
LED Pump
LED Support
resistance
LED ºF
UP
key
SET
key
RIGHT
key
NEW