ASHAPOWER ROVER-5000LV-48V User Manual - Page 11

Browse online or download pdf User Manual for Inverter ASHAPOWER ROVER-5000LV-48V. ASHAPOWER ROVER-5000LV-48V 14 pages. Solar mppt pcu

ASHAPOWER SOLAR PCU-ROVER-SERIES
MENU
BAT-TYPE
1
BATTERY TYPE SELECTION
( Lead acid,Gel,SMF) (0) MARKED
(Lithium,Nicad) (1) MARKED
BAT-AH
2
BATTERY Ah. SETTING
INV-OP-VOLT
3
OUTPUT VOLT OF THE
INVERTER
INV-FLOAT-V
4
FLOAT CHG.VOLT FROM GRID
INV-ABSN-V
5
ABSORPTION CHG. VOLT FROM GRID
INV-BULK-V
6
BULK CHG.VOLT FROM GRID
TYPE OF
SETTINGS
Select optin "0" for Lead acid,SMF,GEL,batteries. Default battery type given is
for Lead acid batteries.
Select option "1" for Lithium and Nicad batteries.
Ashapower recommends to change the charging parameters of this
device to make it compatible for LiFePO4 battery charging
CUSTOMER
Ensure to connect LiFePO4 battery with the help of the battery supplier.
SETTINGS
Always use branded Lithium batteries with BMS.
Never enable Equalization charging for Lifpo4 batteries.
Set the Ah of the connected battery bank to limit the bulk charging
CUSTOMER
time Eg: If 2 X 150Ah battery is connected in series set the value 150Ah
SETTINGS
and if connected in parallel set as 300Ah
CUSTOMER
Limit the output voltage of the inverter.
SETTINGS
Limit the grid charging float voltage recommended for the batteries.
CUSTOMER
Default value given is for C10 grade lead acid batteries.For SMF and Gel
SETTINGS
batteries this value is between 13.0V to 13.8V.Refer bat.user guide
Limit the charging current to the battery if needed. (Inverters are always
CUSTOMER
Limit the absorption charging voltage limit for the connected
SETTINGS
battery.
Limit the maximum bulk charging voltage recommended for
CUSTOMER
the batteries.Refer battery user manual for changing.Default value is for
SETTINGS
C10 solar lead acid batteries.
MAIN FUNCTION SETTINGS
DESCRIPTION
Vers.5.1
RANGE
MIN
DEFAULT
MAX
-
-
"0"
150Ah
10Ah
300Ah
210V
222V
230V
16 .0V
13.8V
13V
13V
14 V
16.5 V
14.6V
13V
16.5V
16V
10.5V
9V