Operating Manual - TM-335 Public Address Mixer/Amplifier
‰ Speaker Wiring
● Before connecting speakers to the TM-335 unit, be sure to disconnect the AC power cable.
● Make certain that the load impedance is not less than the rated impedance indicated.
● Low Z (4
), 25V, and 70V speaker loads should not be wired in combination with each other.
Ω or 8Ω
● Use class 2 wiring.
For the 4
low impedance terminal, connect as shown below, with the negative (-) speaker wire
connected to the COM terminal and the positive (+) speaker wire connected to the 4
from the illustration how two 8
For the 8
low impedance terminal, connect as shown below, with the negative (-) speaker wire
connected to the COM terminal and the positive (+) speaker wire connected to the 8
from the illustration how two 4
in parallel to make an 8
For 25V and 70V terminals, connect with matching transformers as shown below. Note: 230V
export models have 70V and 100V taps instead of 25V and 70V.
speakers can be wired in parallel to make a 4
speakers can be wired in series, or two 16
load.
Note
Ω terminal.
load.
Note
Ω terminal.
speakers can be wired