Low-battery detection:
1. Battery voltage is checked once a minute. When the battery voltage drops to a
certain level, the low-battery icon will display on LCD, and the transmitter
will turn off the appliance. The transmitter will not function anymore until
fresh batteries are installed.
2.
When the batteries are low, the LCD displays a low battery indicator. The low
battery indicator will be displayed in any mode.
3. The transmitter will not operate with low batteries. Change the batteries before
the batteries are too weak for normal operation. TURN THE UNIT OFF
BEFORE REPLACING BATTERIES.
Child-proof protection:
1. Press and hold the ON and OFF buttons simultaneously for 3 seconds to enter
childproof mode as shown in this picture.
2. The transmitter will not send a signal again until childproof mode is deactivated
by pressing the ON and OFF buttons simultaneously for 3 seconds to exit
childproof mode and the Childproof indicator disappears from LCD.
Transmitter Thermal Shutdown:
1. If transmitter measures a room temperature exceeding 99 degrees Fahrenheit, the
LCD will display "HI" and the transmitter will turn off the appliance.
2. Transmitter will not function until the room temperature has dropped below 99
degree Fahrenheit. If transmitter measures a room temperature less than 40
degrees Fahrenheit, the LCD will display "LO" and NO SIGNAL will be sent
to turn on the appliance.
Receiver:
Slide Switch:
1.
ON position: the main burner will ignite and blower will come on when Blower on Delay Time is reached
and fan speed has been enabled; otherwise just burner will ignite until the slide switch is placed in the OFF
or RS position to turn burner off.
2.
RS position: the system will operate if the remote receiver receives a signal from the transmitter.
3.
OFF position, the system is off. If fan speed has been enabled blower will continure to operate until Off
Delay Time expires. The slide switch should be placed in the OFF position if you will be away for an
extended period of time. If the remote receiver is mounted out of children's reach, the OFF position also
functions as a safety device by both turning the system off and rendering the receiver inoperable.