to the OFF position. Make sure the receiver privacy (DIP) switches are set the same. Follow the
instructions on how to set the privacy (DIP) switch setting.
7.
By disabling this feature, your appliance may continue to run unattended.
Optional Wall Cover Plate:
1. Receiver snaps into wall cover plate. The wall plate is mounted by using 2 screws provided.
1.
Light your gas appliance following the appliance lighting instructions that came with the appliance.
Confirm that the pilot light is on; it must be in operation for the remote control to operate the main gas
valve and blower. Appliance control knob must be in the ON position, and appliance ON/OFF switch must
be in OFF position.
2.
Slide the 3 position button on the remote receiver to the ON position and the main gas flame should ignite.
3.
Slide the button to OFF and the main gas flame should extinguish, but the pilot light will remain on.
4.
Slide the button to RS (the center position), then press the ON button on transmitter to turn the system ON.
The main gas flame should ignite and blower should come on after the On Delay Time is reached and fan
speed you desire is selected.
5.
Press the OFF button on transmitter to turn the system to OFF. The flame should extinguish (the pilot light
will remain on) and blower should be off after the Off Delay Time you set.
Symptom
1. Battery icon on
LCD on transmitter.
2. LCD display is
blank
3. LCD display shows
"funny" display
4. Appliance does not
come on.
5. Receiver cannot
receive signal.
6. Blower is not on
after the fireplace is
turned on
50D0112
RCSTEBA Installation & Operating Manual
Rel 1.0 April 2009
TESTING YOUR NEW REMOTE CONTROL SYSTEM
TROUBLESHOOTING
Causes
1. Low Battery
1. Wiring / Electrical Connections
2. Privacy (DIP) switch setting on transmitter
does not match receiver
3. Transmitter measures temperature exceeding
99 degrees Fahrenheit and shows "HI" on LCD
4. Distance between the transmitter and receiver
is more than 30 feet
1. Receiver is installed in an enclosure
1. Blower setting is off
2. Blower delay setting is set too high
1. Replace batteries. Change
batteries every 6 months.
2. Check battery installation or
replace batteries.
3. Press Reset button at the back of
the transmitter.
1. Slide the switch to ON, if
appliance comes ON, wiring is
not the cause.
2. If appliance does not come on,
check wiring connections.
1. Make sure the transmitter and
receiver have the same DIP
switch settings.
1. Move transmitter to a cooler
place and wait until temperature
drops below 99 degree.
1. Make sure the operating distance
is less than 30 feet
1. Make sure the receiver is not
located inside to tight of an
enclosure.
1. Press FAN key to select Fan
speed you desire.
2. Press and hold FAN key to set
Page 10 of 10