SPECIFICATIONS

Alimentazione / Input Voltage
Consumo / Current Drain (Alarm/Stand-By)
Current drain with Lamp /consumo con lampada
Grado di Protezione IP / IP Grade
Portata in lunghezza / Coverage
Portata in larghezza / Angle
Piroelettrico / PIR
Lente (fasci e livelli) / Lens (beams and levels)
Durata allarme / Alarm period
Antiapertura / Anti-opening
Contatto di allarme / Alarm's Contact
Contatto di tamper / Tamper Switch
Temperatura di esercizio / Operating Temperature
RFI Protezione / Protection
Led WALK TEST (MW and PIR)
Cover / Housing
Dimensioni / Dimensions
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and
due to, but not limited to, any or all of the following: tampering, electrical or communication disruption or improper use, it
is possible for the product/system to fail to prevent burglary, rubbery, fire or otherwise. A properly installed and maintained
alarm system can only reduce the risk that this happens.
9 to 15 Vdc
(12 mA / 23mA) @ 13.8 Vdc
260mA @13.8 Vdc
IP42
2 - .35 m
165°
2 elementi / 2 elements
6 patterns on 1 levels
4 sec.
s
100 mA - 40 V - 16 Ω
Max 40 mA - 30 Vdc
From -25 °C to +55 °C
10 V / m (20 /1000 MHz)
S
ABS
L145 x H37 x P30 mm