FLOJET 2100-750 Specificaties

Blader online of download pdf Specificaties voor {categorie_naam} FLOJET 2100-750. FLOJET 2100-750 4 pagina's. 2100 series duplex diaphragm design automatic water system pump & shower drain • general purpose pump

FLOJET 2100-750 Specificaties
FEATURES
• Self-Priming
• Dry Running
• Automatic Operation
• Models Meet U.S.C.G. Electrical Standards
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing. CE Models
are fully suppressed.
Pump: Two chamber diaphragm design; Self-priming
up to 6 ft. suction lift; Pump able to run dry
without damage.
Port:
Pump housing inlet and outlet are 3/8" NPT
female threads.
MODEL*
VOLTS
2100-12
12V dc
2100-694**
12V dc
2100-740
24V dc
2100-750
12V dc
*CE fully suppressed models are identified by a prefix "R" and a CE mark on the label. (i.e. R2100-740)
Self Declaration Of Conformance (SDOC) is available upon request.
**Shower Drain Model only, does not include port connectors, see Accessories to order connectors.
OPERATION FOR
WATER SYSTEM PUMPS
The FLOJET 2100 series pumps are automatic demand
pumps. They will automatically turn on when a fixture is
opened and turn off when all fixtures are closed.
When starting from a completely drained system allow
time for the demand pump to fill the hot water tank. After
refilling the tank the pump is reprimed by opening a
fixture. Allow air to vent and close fixture when water
flow is steady. Faucet strainers and aerators should be
cleaned regularly.
AMP DRAW
@ 10 psi (0.7 bar)
2.5
2.5
1.5
2.5
Duplex Diaphragm Design
Automatic Water System Pump &
Shower Drain • General Purpose Pump
Pump Series
Dimensions - Inches (mm)
Height
2100-XXX
3.75 (95) 3.25 (83)
FUSE
FLOW
AMPS
GPM (l/min)
7
2.3 (8.7)
7
2.3 (8.7)
5
2.3 (8.7)
7
2.3 (8.7)
OPERATION FOR
THE SHOWER DRAIN PUMP
Model 2100-694 is a utility/shower drain pump. The
pump will not turn off automatically. Your shower drain
pump is designed to self-prime up to 6 feet suction lift
(vertical distance from shower pan to pump inlet). It is
recommended you utilize a "lighted" on-off switch so
that pump is turned off when not in use. The pump is
able to run dry (no liquid) for extended periods with no
damage to the pump, however this could cause
needless battery drain.
Models2100 Series
Width
Length
8.2 (208) 3.3 (1.5)
PRESSURE SWITCH PSI (BAR)
ON
15 (1)
30 (2)
No Pressure Switch
15 (1)
30 (2)
15 (1)
30 (2)
Weight
lb. (kg)
OFF