The pool sensor must be fitted into the heating circuit, as close to the pool as practical,
preferably in a position out of direct sunlight. It is recommended that a 14.5mm hole
be drilled in the side of the PVC pipe, not the top of the pipe where water will collect.
This can be carried out using a Dontek PD01 grinding drill or a pilot hole drilled, then a
14.0mm drill-bit spinning in a counter clockwise direction to minimize the chance of
POOL
shattering pipe.
SENSOR
Insert the grommet into the pipe and gently push in the sensor barb. Ideally ~30cm of
the cable from the sensor should be tied to the shaded side of the pipe to prevent
extreme ambient conditions leeching into the sensor via the copper in the cable. The
blue sensor plug is to be fitted to the plug socket marked POOL.
The roof sensor must be fitted into a small piece of collector material away from the
main collector but on the same aspect, preferably no more than 50cm from the roof
gutter (for ease of sensor replacement). If required, the roof sensor can be on a
ROOF
different roof to the solar collector as long as the alignment to the sun is similar to the
SENSOR
solar collector. For encapsulated collector panels, use the manufacturer's instructions
for roof sensor placement. The red sensor plug is to be fitted to the plug socket
marked ROOF.
All excess cable must be removed; coils of cable are not permitted under any
circumstances and must not be tied to 240V wiring. If the cable is to be extended with
SENSOR
non-genuine cable a size of 14/020 should be used. Any cable joins should be soldered.
Heat shrink is to be used over soldered joints to eliminate moisture ingress, and the
NOTES
cable end is to be refitted to the plug sockets. Once cables have been correctly fitted
the unit can be then turned on.

BASE PLATE

Circulation Pump plugs
in here.
AQUASMART 5 SV v1.4
Solar Booster Pump
plugs in here.
Valve Actuator
plugs in here.
3 Pin Port
Roof Sensor
Pool Sensor
plugs in here.
plugs in here.
Heater Interlock
cable plugs in here
2 Pin Port
3