OPTIONAL – USE OF HACCP / BLUETOOTH MODULE
EVconnect is an easy solution that helps to easily get HACCP temperature and to
manage the temperature alarms.
EVconnect is made of the EVLINK, a memory an transmission module (provided
with 16Mb memory, real time clock and Bluetooth 4.0 transmission module) and of
the EVconnect App for Android 4.4 devices.
EVLINK is available as an accessory and the App is freely downloadable on Google
Play (an Apple version is under development).
This solution is capable of storing at least one year of recordings, that the user
can download via Bluetooth into a smartphone or tablet without losing data.
Temperature graph is immediately available as far as the possibility of send via
e-mail the information as image or .csv file for Excel (r).
The EVLINK module should be connected to the EVCO thermostat using the TTL
port on the side of the same. Do not try to extend the wirings. For full installation
and use instructions see the notes provided with the EVLINK.

CLEANING AND MAINTENANCE

Always disconnect any electrical connection before you clean and service the units.
Clean the unit before first time use and at regular intervals thereafter.
IMPORTANT: do not wet the electronic components, are not water proof!
Use only neutral (food safe) cleaning agents. Never use aggressive or caustic
cleaning agents, scouring powder, steel wool, abrasive sponges or chemical
solvents. Never use brushes, scouring pads or hard or pointed tools to remove ice
or to loosen objects which have frozen in place
The use of a high pressure cleaner and/or steam jet is strictly forbidden.
Clean the unit (inside and outside) with a neutral detergent, rinse with lukewarm
water and dry it before any long term storage unplugged.
Humidity can form frost in the interior of the cooling device. This reduces the
cooling capacity. Defrost the device in good time to avoid this. Wipe off the melted
water with a damp cloth.
The hermetic cooling circuit of the units are maintenance free. No periodical
maintenance is requested.

LIMITED LIABILITY

Euroengel srl has an indirect Limited Warranty and Liability policy, enforced via the
local importers. Ask for specific conditions.
Warranty is limited at Euroengel's option to repair or replacement with new or
remanufactured parts of any parts which are found by Euroengel to have been
defective under normal use and service within the specified warranty period.
Euroengel will not be held liable for claims for damage resulting from the following: