Drilling. Ensure that the holes are marked as accurately as possible. Set the Mounting Plate
aside after marking the drilling locations.
2.1.3
Use a hammer drill to make 3/8 inch diameter holes at each of the 4 mounting locations
marked in the previous step. A hammer drill is required for this operation. Clean the holes
of all concrete dust using a wire brush and compressed air or a vacuum. Install the 3/8-16
concrete anchors in each of the 4 drilled holes by hammering them in to the appropriate
depth. Leave the nut on while hammering so that the threads of the concrete anchor are
protected and not damaged. Ensure that the Mounting Plate fits over the concrete anchors,
and then set it aside.
Warnings:
The supplied anchors are for concrete only. Do not attempt to use in brick, block or other
materials. Other fasteners are required for brick, block and other materials and are not
included. Minimum engagement of the supplied concrete anchors is 2" [50 mm]. If the
provided fasteners are not appropriate for the installation surface, it is the responsibility of
the customer to specify and source appropriate fasteners for the application.
Holes for concrete anchors should be drilled a minimum of 1/2 inch [13 mm] deeper than
the overall length of the anchor, provided that the mounting surface can tolerate such a
depth. This allows the anchor to be hammered flush should a mistake be made or a location
change be necessary.