Baumer Hubner Berlin PMG10 Bedieningshandleiding - Pagina 27

Blader online of download pdf Bedieningshandleiding voor {categorie_naam} Baumer Hubner Berlin PMG10. Baumer Hubner Berlin PMG10 44 pagina's. Absolute encoder
Ook voor Baumer Hubner Berlin PMG10: Montage- en bedieningsinstructies (32 pagina's), Montage- en bedieningsinstructies (32 pagina's)

Baumer Hubner Berlin PMG10 Bedieningshandleiding
Baumer Hübner
6.8.3

Assignment of connection elements second terminal box

NOTICE
Operating voltage present at the outputs results in encoder damage.
The encoder might be damaged by any operating voltage being present at the outputs.
a) Make sure that no operating voltage is present at the outputs.
Additional incremental output 2 (optional)
Speed switch (optional)
The TTL/HTL output (Vin = Vout) at the additional incremental output 2 is galvanically isolated
and requires separate voltage supply.
1
2
3
4
5
6
7
Ill. 12: Pin assignment
1
3
5
7
9
11
13
I
Speed switch (optional)
II
Additional output incremental (optional)
6.9

Electrical connection with radial flange connector

6.9.1

Connecting the supply cable

NOTICE
Equipment damage due to dust or moisture
Inappropriate cable diameters may entail ingress of dust or moisture. In this case, the protection
class is no longer ensured causing device failure or malfunction.
a) Use only appropriately sized cables to make sure the specified protection class is being en-
sured.
INFO
Connection cables are not included in delivery.
V1 | PMG10 & PMG10P SSI
I
dnu / SP+ 
II
dnu / A− 
II
dnu / B− 
II
0 V 
II
nE+ 
II
dnu / R+ 
dnu
8
9
10
11
12
13
14
2
dnu / A+ 
4
dnu / B+ 
II
6
Ub 
8
dnu / SP− 
II
10
nE− 
12
dnu / R− 
14
dnu
Operating Manual
Electrical installation
II
II
I
II
|
6
27