Baumer Hubner EtherNet/IP HMG10 Bedieningshandleiding - Pagina 38

Blader online of download pdf Bedieningshandleiding voor {categorie_naam} Baumer Hubner EtherNet/IP HMG10. Baumer Hubner EtherNet/IP HMG10 44 pagina's.

Baumer Hubner EtherNet/IP HMG10 Bedieningshandleiding
7
|
Disassembly
7.2

Detaching the encoder from through-hollow shaft

DANGER
Burns caused by heat
The device heats up at high torque. There is a risk of getting burned after use.
a) Avoid overheating the device.
b) Wear suitable gloves.
Ill. 11: Detaching the encoder from the through-hollow shaft
1
Self-locking nut M6 (ISO 10511)
3
Grounding strap
5
Through hollow shaft
7
Torque arm
9
Washer B6.4 for grounding strap (ISO
7090)
Tool
1,6×8 mm
n
n
10 mm
n
Instruction:
a) Loosen the Torx screw at clamping ring. Do not unscrew the screw completely.
b) Loosen the self-locking nut on the torque arm
c) Loosen the cheese-head screw at grounding strap.
d) Slide the encoder off the shaft.
38
1
4
10 mm
Operating Manual
2
3
1
4
9
8
4
7
1
2
Threaded rod M6 (variable length ≤ 210
mm)
4
Washer B6.4 (ISO 7090)
6
Torx screw M3x12 mm (ISO 7045)
8
Cheese-head screw M6x8 mm for
grounding strap (ISO 1207)
>113 mm
5 6
HMG10 & HMG10P EtherNet/IP | V1, T1
Baumer Hübner