Description
4
Description
4.1
Structure
The sensor measures the conductivity and temperature of liquids and optionally calculates con-
centration values.
Ill. 2: Structure
1
Display
3
Process connection
5
Medium bore hole
The sensor consists of display, transmitter and sensing tip.
System parameters and measured values are indicated on the display.
Sensor parameterization is either via the display or using FlexProgram or the IO-Link master.
Sensor mount is by screwing-in the thread.
Measurements are made by the sensor's measuring hole and temperature probe.
Also see about this
2 Operating and display elements [} 9]
2 Functional description [} 9]
4.2
Product versions
Version
PAC50H
PAC50S
The sensor is available in different variants:
Short sensor tip
n
Medium sensor tip
n
Long sensor tip
n
In addition, each sensor variant is available with or without display.
In addition, each sensor variant is available with 90° rotated hole orientation.