CYCLE COUNTER FOR AIR OPERATED DOUBLE
DIAPHRAGM PUMPS
OPERATIONAL DESCRIPTION:
The cycle counter model operates via a magnetically actuated
proximity-switch installed into the main air-valve. The switch closes
when the spool is in the down position, thus allowing open loop
metering applications.