Dover PSG ALL-FLO A200 Instalação, operação e manutenção - Página 17

Procurar online ou descarregar pdf Instalação, operação e manutenção para Bomba de água Dover PSG ALL-FLO A200. Dover PSG ALL-FLO A200 20 páginas. Plastic 1/4 inch air-operated double-diaphragm pump

Dover PSG ALL-FLO A200 Instalação, operação e manutenção
CYCLE COUNTER FOR AIR OPERATED DOUBLE
DIAPHRAGM PUMPS
OPERATIONAL DESCRIPTION:
The cycle counter model operates via a magnetically actuated
proximity-switch installed into the main air-valve. The switch closes
when the spool is in the down position, thus allowing open loop
metering applications.
ALF-11010-E-01
REV
17
DESCRIPTION
BY
DEFAU
TOLER
DECIMAL
.XX
.XXX
ANGULA
0.
DATE
All-Flo