Amphenol Tempsonics Level Plus LLE Bedieningshandleiding - Pagina 19
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} Amphenol Tempsonics Level Plus LLE. Amphenol Tempsonics Level Plus LLE 20 pagina's. Magnetostrictive liquid level transmitters with temposonics technology
10. Spare Parts
Below are the spare parts list for the LLE that are included as part of
the model number. Please contact Temposonics Technical Support
with any questions.
Stop Collar
7 mm O-ring
10 mm O-ring
7 mm stop collar
10 mm stop collar
Cable
Analog
IO-Link
CANopen
SSI
Process Connection
SAE 5 Bolt
1 " NPT
1,5 " NPT
2 " NPT
2,5 " NPT
3 " NPT
4 " NPT
2 " 150# RF Flange
3 " 150# RF Flange
4 " 150# RF Flange
5 " 150# RF Flange
6 " 150# RF Flange
Fig. 9: Spare parts
11. Interface
11.1 Analog output
The analog output for LLE is either single output or dual output
dependent on the order code. The output codes starting with V are
voltage outputs and the codes starting with A are current outputs. The
first digit is the voltage or current closest to the head and the second
is closet to the tip. For example, A010 4..20mA has the 4mA set point
closest to the head and 20 mA closest to the tip. The analog output
cannot be adjusted.
Part number
562354
562355
562392
562348
Part number
370675
370675
370675
370676
Part number
404205
562349-1
562349-2
562349-3
562349-4
562349-5
562349-3
560465-1
560465-2
560465-3
560465-4
560465-5
11.2 IO-Link output
IO-Link is an open standard according to IEC 61131-9. It is a serial,
bi-directional point-to-point connection for signal transmission and
energy supply. The bi-directional communication enables consistent
communication between sensors and the controller as well as
consistent diagnostic information down to the sensor level. For
additional details on setup please consult the EH IO Link manual
551485 section 5.
The measurement direction of IO Link can be programmed by the
customer. The Parameter Measuring Direction, Index 0x73, can be set
to False to measure from the housing to the tip of the pipe or True to
measure from the tip of the pipe to the housing.
11.3 SSI output
The SSI output is available as either 24 or 25 bit, Binary or Gray code,
and 0.1 mm resolution. The measurement direction is set to measure
up from the tip of the pipe.
11.4 CANopen output
CANbus (Controller Area Network) is designed for high-speed data
exchange at machine level. CAN is a vendor independent open
fieldbus system, based on standard ISO 11898. CAN specifies the
functional and technical parameters with which the intelligent digital
automation devices can be networked via a master-slave serial link
by using a communication profile. Protocol architecture of functional
and applications data is oriented to the OSI reference model (ISO
7498). Bus technology is administrated and developed by the user
organisation CiA (CAN in Automation)
The CANOpen output of the LLE is avaialbe with or without integral
termination, selectable Baud rate of 1000, 500, 250, or 125 kBit/s.
The resolution is set at 0.02 mm and the output can be configured for
1 or 2 floats. The measurement direction is set to measure away from
the electronic housing and towards the tip of the pipe
I
19
I
Level Plus
LLE
®
Operation Manual