DRAIN INSTALLATION
The drain outlet on the dehumidifier can be hard piped using a 3/4" PVC Slip x 3/4" MNPT fitting and 3/4" nominal drain tubing or the provided 3/4"
MNPT x 3/4" hose barb fitting . 3/4" clear PVC tubing can be used to drain the dehumidifier . Always maintain a constant downward slope from the
dehumidifier to the drain and do not allow soft tubing to curl up which may result in air lock .
NOTE: PTFE thread seal tape is recommended for the threaded connection and hand tighten only . If hard pipe is used, PVC primer and cement is
recommended for the slip fit connection . Remove drain insert before priming and gluing in the PVC fitting . Replace drain insert after PVC glue has
fully dried .
CAUTION
Do not damage drain insert. The drain insert is a critical feature of the dehumidifier drain management system.
WARNING
Running the dehumidifier without the drain insert can lead to condensate leaks. See FIGURE 7.
FIGURE 7 – DRAIN INSERT
DRAIN INSERT
90-2607
6