Electrolux Air-O-Chill 727153 Handleiding voor gebruik en onderhoud - Pagina 16
Blader online of download pdf Handleiding voor gebruik en onderhoud voor {categorie_naam} Electrolux Air-O-Chill 727153. Electrolux Air-O-Chill 727153 27 pagina's. Blast chiller-freezer 201 (220 lbs.) 208 v/3p/60hz – 20a
Ook voor Electrolux Air-O-Chill 727153: Specificatieblad (2 pagina's)
program indicator light
• to start the program, press the
The user can edit some of the cycle parameters and save the
changes:
- for blast chilling, the user can edit the chamber chilling time/
setpoint and save it in the memory, from where it can
subsequently be retrieved (see section C.2.2.3 and C.2.2.4).
- for positive maintenance, the user can set the chamber
setpoint.
C.2.2.5 Modification of chilling time
Chilling time is modifiable in the following cases:
1) during setting of a programme (P1 or P2)
2) during the selection phase of a chilling cycle
3) during actual chilling (can only be decreased).
For modification, proceed as follows:
• press the key
• the display will flash to show that modification phase is active;
• set the desired value using the keys
• press the key
will take place automatically after five seconds of inactivity.
C.2.2.6 Modification of cell temperature
• Chilling cycles: the set point can be modified only during
selection of a custom cycle or during "turbo cooling".
• Holding cycles (all).
In all cases proceed as follows:
• press the key
• the display will flash to show that modification phase is active;
• set the desired value using the keys
• press the key
If a selection is not made after 5 seconds, the last value
displayed will be confirmed automatically.
switches on.
button.
for two seconds;
;
to confirm the value. Confirmation
for two seconds;
;
to confirm the value.
C.2.2.7 Displaying the temperature setpoint and chilling end
time
When a cycle is running, the user can view the temperature
setpoint and chilling end time by pressing buttons
and
C.2.2.8 Changing the Standard selection
To select a Standard, e.g. the Electrolux Food Safe Mode 2,
press the
button, press the
Standard utility is selected,
press the
button to enter, press the
the Standard
either press the
confirm the selection or it will be confirmed automatically if
nothing is pressed for 12 seconds.
C.2.2.9 Editing USER parameters
To edit a parameter, select the utility:
• press the
button;
• the display blinks to show that the parameter is in 'edit' mode;
• press the
setting range;
• press the button to confirm the settings; if a selection is not
made after 5 seconds, the last value displayed will be confirmed
automatically, or press
NOTE: the parameters can be edited ONLY if no cycle is running.
If a cycle is running, the utility will enable only the display of the
parameters.
See section D.6 for the "List of user parameters".
C.2.3 BLAST CHILLING/PRESERVATION CYCLE
When the chilling or freezing cycle has finished, the appliance
will automatically go into the preservation stage. It is important
for the chilled food to be kept in an appropriate way, maintaining
a preservation temperature suitable for the type of food chilled.
16
simultaneously.
button until the
button again to
buttons to change the value within the
again.
button to select