Communications Specialties Scan Do 1024 Gebruikershandleiding - Pagina 6

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Communications Specialties Scan Do 1024. Communications Specialties Scan Do 1024 16 pagina's. Computer to video scan converter

VGA and Mac
Resolutions Supported
How to Activate
Test Signals
Page 6

OPERATION

Scan Do 1024 is designed to be easy to use, reliable,
intelligent, and high performance. You will find the operation
to be intuitive. However, we suggest you read the following
pages to fully understand how Scan Do 1024 operates and
to take advantage of all its features. If after becoming familiar
with its operation and features you still have questions,
please let us know. If you have any suggestions to improve
its operation or find any features of particular value, we would
like to know that as well.
POWER: This indicator tells when power is present and
Scan Do 1024 is ON. If this light is glowing dim or not at all,
it is an indication that something might be wrong with the
external power supply.
INPUT: This indicator tells when a valid computer signal is
present at the VGA IN or MAC IN connector on the rear panel.
The following is a list of all the valid VGA and Mac display
resolutions and their vertical refresh rates that Scan Do 1024
will detect and convert. If Scan Do 1024 does not detect one
of these resolutions on its input, it will display a flat blue
screen on its output and the INPUT light will flash.
VGA: 320x200 @ 70Hz
640x200 @ 70Hz
640x350 @ 70, 84, 87Hz 800x600 @ 56, 60, 72
720x350 @ 70, 84, 87Hz
720x400 @ 70Hz
MAC: 640x480 @ 66Hz
832x624 @ 75 Hz
TEST: This button will force Scan Do 1024 to generate one
of two test signals on its COMPOSITE and S-VIDEO outputs
(not available on the RGB output). Press the switch once and
the indicator light will go ON to show the color bar signal.
Press it again, and the output will now be a gray scale ramp.
Press it a third time and the indicator light will go OFF and the
outputs will now show the computer input.
NOTE: If the TEST button is pressed in continuously for 5
seconds, Scan Do 1024 will automatically reset all functions.
Scan Do 1024 User's Manual
640x480 @ 60, 72, 73
& 75 Hz
73, & 75 Hz
1024x768 @ 60, 70, 72
73, & 75 Hz
1024x768 @ 60 & 75 Hz