Anderson ANM75 Bedieningshandleiding - Pagina 7
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} Anderson ANM75. Anderson ANM75 18 pagina's.
Fig 4. ANM75 Series Burner Input Curve
10. Burner Installation
10.1 Storage:
1. Make sure that the area is clean.
2. Store the components in a cool, clean, dry room.
3. Keep the components in the original package as long as possible
10.2 Handing
1. Make sure that the components are clean and free of damage.
2. Protect the components from weather, damage, dirt and moisture.
3. Protect the components from excessive temperatures and humidity.
4. Use appropriate support equipment, i.e., harnesses, straps, chains etc. when lifting
burner components.
10.3 Pre–Installation Checklist
If there are corrosive fumes or materials in the surrounding air, find a clean air source
to supply to the burner. Observe ambient temperature limits as stated in Datasheet.
Combustion air from outside of burner room, needs at least 6 cm
sufficient fresh, outdoor combustion air.
Combustion air from inside duct, there must be a minimum of 18% O
process air flow to ensure proper burner performance.
Do not allow exhaust gases to accumulate in the work area. Provide a means for
exhausting these gases from the building by blower, install the burner so it may be
easily accessed for inspection.
10.4 Environment
Be sure the burner operating environment matches the original operating
specifications. Check the following items:
– Voltage, frequency, and stability of electrical power
Anderson Thermal Soluions(Suzhou)Co. ,Ltd.
Anderson Thermal Solutions – ANM75 Burner Operation Manual
Fig5. ANM75 Series Burner Flame Length Curve
5
2
per 1 kW to supply
present in the
2