Atlas Copco ETD M120ABL V2 Product Instructies - Pagina 11

Blader online of download pdf Product Instructies voor {categorie_naam} Atlas Copco ETD M120ABL V2. Atlas Copco ETD M120ABL V2 16 pagina's.

ETD M120ABL V2

Service

Preventing ESD problems

The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.

Maintenance instructions

Service recommendations

Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guidelines:
Clean appropriate parts accurately
Replace any defective or worn parts

Preventive maintenance

Recommended interval between actions:
Valid at normal usage of the tool at a load up to 70% of maximum torque.
Interval
1.500.000 cycles or 1 year
2.000.000 cycles
3.000.000 cycles

Instructions

Service equipment:
Normal workshop equipment.
Necessary special equipment as shown in the exploded views/tables.
For testing a calibration rig is recommended.
PC with internet connection to be able to download necessary keys.
EN
© Atlas Copco Industrial Technique AB - 9836 7911 01
Action
Calibrate the tool
Exchange front part
Exchange motor
Service
11