Atlas Copco ETD M120ABL V2 제품 지침 - 페이지 11
{카테고리_이름} Atlas Copco ETD M120ABL V2에 대한 제품 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlas Copco ETD M120ABL V2 16 페이지.
ETD M120ABL V2
Service
Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.
Maintenance instructions
Service recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guidelines:
■
Clean appropriate parts accurately
■
Replace any defective or worn parts
Preventive maintenance
Recommended interval between actions:
Valid at normal usage of the tool at a load up to 70% of maximum torque.
Interval
1.500.000 cycles or 1 year
2.000.000 cycles
3.000.000 cycles
Instructions
Service equipment:
■
Normal workshop equipment.
■
Necessary special equipment as shown in the exploded views/tables.
■
For testing a calibration rig is recommended.
■
PC with internet connection to be able to download necessary keys.
EN
© Atlas Copco Industrial Technique AB - 9836 7911 01
Action
Calibrate the tool
Exchange front part
Exchange motor
Service
11