1)Before changing bits from BK Series screwdriver, make sure the Forward / Reverse switch stays at
"OFF"position.
The screwdriver must be unplugged.
2) To avoid damaging the housing of screwdriver, do not allow chemicals get in touch with housing of screwdriver. Ex.: Acetone,
benzene, thinner, trichloroethylene ketone, and other similar chemicals.
3) Use screwdriver carefully, do not drop or abuse. It would be better to use with the spring balancer. If without spring balancer,
you can place the screwdriver in the suspension rack.
4) Assemble / disassemble bits : Only use fingers pull up the bit sleeve to release bits. ; Place back the bit sleeve to lock the bit
holder.
Attention : Make sure the power is off, or the Forward / Reverse switch stays at "OFF"position when assemble or disassemble
bits.
5)Connect the plug to the socket. Attention : It will cause an electric shock if the plug or the hand is wet.
6)You can adjust the torque by the torque adjuster ring. The number on the scale is not equal to the real torque, please refer to our
torque range chart, or test the torque by our torque meter.
Attention : Hi gear Do not adjust the torque setting higher than 8 on the torque scale.
Lo gear Do not adjust the torque setting higher than 4 on the torque scale.
7) a)MY9-0206L Series Trigger Start Type screwdriver : When fasten a screw, please set Forward / Reverse
Switch to "Forward".
(If the screw is reversed-thread screw, please set Forward / Reverse switch to "Reverse".) Point at the place of the bit and the
screw, press the trigger to start; When torque reaches user's setting, the clutch will shut out automatically, the power will shut
off and the motor breaks immediately, the screwdriver stop running.
b) MY9-0206P Series Push Start Type screwdriver : When fasten a screw, please set Forward / Reverse switch to "Forward".
(If the screw is reversed-thread screw, please set Forward / Reverse switch to "Reverse".) Point at the place of the bit and the
screw, push down the screwdriver to start; When torque reaches user's setting, the clutch will shut out automatically, the
power will shut off and the motor breaks immediately, the screwdriver stop running.
8) Trigger Start Type screwdriver : When loosen a fastened screw, please set Forward / Reverse switch to "Reverse".
(If the screw is reversed-thread screw, please set Forward / Reverse switch to "Forward".)
Follow the above operation, after loosening the screw, release the trigger to stop.
Push Start Type screwdriver : When loosen a fastened screw, please set Forward / Reverse switch to "Reverse"
(If the screw is reversed-thread screw, please set Forward / Reverse switch to "Forward".)
Follow the above operation, after loosening the screw, stop pushing the screwdriver to stop.
9) Operation frequency: The original setting of the frequency is 1 sec on / 3 sec off. The number of screw fastened is about 15 pcs.
Over frequently using makes the motor overheated and damage to screwdriver.
Enough heat-dissipation is good for screwdriver.
Slow speed Duty Cycle Conversion (for reference)
Based on 1000 rpm, 1 second ON/3 seconds OFF. For example, the duty cycle for 350rpm,1000-350=650,
650/1000%=65%
ON= 1*1.65= 1.65,OFF =3*1.65 =4.95 (rounded value) =2 seconds ON / 5 seconds OFF
This tool is intended for a duty cycle of 2.0 sec on, 5.0 sec off.
Slow speed (rpm)
operation frequency
900
850
800
750
700
650
10) Do not use this screwdriver to fasten wooden screws.
11) Do not operate the Forward / Reverse switch when the motor is running.
12) Whenever a screwdriver is not being used, move the Forward / Reverse switch to the "OFF" position and unplug the screwdriver.
13) Keep staying aware.
Pay attention on your work, check safety measures and every part is workable before using screwdrivers, to make sure
screwdrivers can work under original design function.
14) Use cable for the external counter and I/O box is shield cable for avoidance of electrical interference
Use Anti-interference lines.
Operations Cautions
Slow speed (rpm)
1.0 ON 3.0 OFF
1.0 ON 3.0 OFF
1.0 ON 3.0 OFF
1.0 ON 3.0 OFF
1.0 ON 3.0 OFF
1.0 ON 3.0 OFF
operation frequency
600
1.0 ON 3.0 OFF
550
2.0 ON 5.0 OFF
500
2.0 ON 5.0 OFF
450
2.0 ON 5.0 OFF
400
2.0 ON 5.0 OFF
350
2.0 ON 5.0 OFF
5
Slow speed (rpm)
operation frequency
300
2.0 ON 5.0 OFF
250
2.0 ON 5.0 OFF
200
2.0 ON 5.0 OFF
150
2.0 ON 5.0 OFF
100
2.0 ON 5.0 OFF