Smoke
WLS906-433
The WLS906-433 requires six Eveready Energizer AA
Detectors
batteries. To replace the batteries, remove the detector
from the mounting plate by pushing the locking tab
and turning the detector counter-clockwise.
Hold the unit with the battery compartment facing
you, and the imprinted wording right-side up. Install
the first two batteries in the row nearest to you, with
the + terminals facing left. Next, install the middle two
batteries with the + terminals facing to the right. Place
your thumb over the centre of these four batteries to
keep them in place. Install the last two batteries, with
their + terminals facing to the left, by snapping them past the nylon retainer.
Wireless Keys
WLS919-433
The WLS919 wireless key requires two lithium CR2032 batter-
ies. To replace the batteries, open the key's plastic housing by
inserting a flathead screwdriver along the side of the unit;
carefully twist the screwdriver to separate the top and bottom
plastic. Remove the old batteries. Insert the new batteries according to the dia-
gram at right and reassemble the key's plastic housing.
NOTE: The polarity of the batteries must be observed.
After
After you change the batteries on your system, the system may announce trouble
Installing
conditions. A zone tamper should be displayed for each detector that had batter-
New Batteries
ies changed. A zone fault may also be displayed and announced for these detec-
tors. Refer to Checking Trouble Conditions on page 19 for information on
checking Zone Faults and Zone Tampers.
Be sure to perform a complete test of your system after new batteries are installed
to ensure that all detectors are working properly (see Testing Your System on
page 20).
28

Fire Detection

This NT9010 controller is capable of monitoring fire detection devices such as
smoke detectors and providing a warning if a fire condition is detected. Good fire
detection depends on having an adequate number of detectors placed in appro-
priate locations. The system must be installed in accordance with NFPA 72
(N.F.P.A., Batterymarch Park, Quincey MA 02269). Carefully review Fire Safety on
page 23.
NOTE: Your installer must enable the fire detection portion of this equip-
ment for it to work.

Testing

To make sure your system continues to work as intended, you must test your sys-
tem weekly. Please refer to Testing Your System on page 20. If your system does
not work correctly, call your installer for service.
Remote
This system can send alarms, troubles and emergency messages over telephone
Monitoring
lines to a central station. If you accidentally initiate an alarm, immediately call the
central station to prevent an unnecessary response.
NOTE: Your installer must enable remote monitoring for it to work.

Maintenance

With normal use, the system requires minimum maintenance, but please note the
following points:
1. Do not wash the security equipment with a wet cloth. Light dusting with a
slightly moistened cloth should remove normal dust accumulations.
2. Use the system test described in Testing Your System on page 20 to check
the battery condition of the NT9010 controller. We recommend that the stand-
by battery be replaced every three years.
3. Consult the manufacturer's literature for testing and maintenance instructions
for other system devices such as smoke detectors, motion detectors, and glass-
break detectors. For instructions on replacing detector batteries, see Replacing
Batteries on page 26.
NOTE: The NT9010 is only compatible with DSC wireless devices.