General Precautions
♦ All insulation of leads connected to output terminals should have at least a 300V rating.
♦ Do not use clip leads in the connections. They are very dangerous for high-voltage work.
Acceptable Load Types
♦ This Amplifier is designed to drive capacitive loads only. Do not use with resistive loads.
The driver will only work properly when a capacitive load is connected to the output.
♦ Never connect an inductive or a resistive load to the unit. This would cause a short-lived
high-current pulse at the output and would damage the unit.
Short Circuit Damage
♦ Although the VF-150 OEM is protected against a short circuit on the output, it is
recommended that a short circuit condition be avoided.
♦ Never connect an "earth ground" lead (e.g., an oscilloscope ground lead) to the output
terminal. This can cause high current at the output and possible damage to the unit.
♦ If the user desires to observe the output signals using a voltage meter or an oscilloscope, the
user must ensure that the meter or oscilloscope has an input impedance of at least 1 MΩ.
Smaller input impedances could damage the unit.
RECOMMENDED OPERATION
Intended Use
DSM's VF-150 OEM is intended to drive piezoelectric (capacitive) loads of the following types:
• Operating range –100 to +100 V
• Operating range –40 to +200 V
• Operating range –30 to +150 V
• Operating range –20 to +120 V
External power supply determines configuration. The input rail voltages should both be 5 to 10
Volts beyond the operating range. For example if -30 to +150 Volt operation is requred, typical
rail voltages would be -40 and +160 Volts. Two modes of operation are supported; the output
voltage can be set using an analog input voltage with nominal gain of 58, or the output voltage
can be set using a serial communication interface. Operation is decribed in more detail, below.
WARNING!