DSM VF-150 OEM Gebruikershandleiding - Pagina 5
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} DSM VF-150 OEM. DSM VF-150 OEM 7 pagina's.
Instructions for Use
Start-Up / Shut-Down Procedure:
DSM recommends that the unit be connected to a load (capacitive, such as a piezoelectric device
of the appropriate rating) during start-up and while the unit is running; operating without a load
can be damaging to the unit's circuitry.
Attach a standard load (i.e., a piezoelectric actuator with two lead wires for power and ground) to
the VF-150 OEM. Typically, the piezoelectric material manufacturer will designate the "live",
"hot" or "positive" electrode with red lead wire and/or a visible mark on the piezo material to
distinguish this electrode from the ground electrode.
CAUTION: When the VF-150 OEM is powered, pins can have voltages up to 200 V
(depending on power supply used).
VF-150 OEM Mounting and Connection Diagram:
(top side of customer supplied board pictured)
Connections:
CN201 (20 pin connector) PN FCI 10106813-021112LF
1, 2
Analog Input
3, 4
Analog Ground
5, 6
Amplifier TX
7, 8
Amplifier RX
9, 10
DAC CS
11, 12
DAC MOSI
13, 14
DAC CLK
15 thru 18
Digital Ground
19, 20
5VDC 1A
*Logic inputs are 3.3 and 5 V tolerant.
*Outputs are 5 V logic level
Hardware Version V131028
114 Southeast Parkway Ct.
Ste 160
Franklin, TN 37064
Tel: 615/595-6665
Fax: 615/595-6610
4