Auber Instruments JSL-72 Gebruiksaanwijzing - Pagina 3
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Auber Instruments JSL-72. Auber Instruments JSL-72 3 pagina's. Timer for coffee grinder
Ook voor Auber Instruments JSL-72: Gebruiksaanwijzing (3 pagina's)
AUBER INSTRUMENTS
JSL-72 Instruction Manual
120VAC
Figure 4. Wiring example of JSL-72. Power (120 or 240V AC) is sent to terminal 6 and 7.The external switches should be
momentary type. The manual remote switch is the only access to control the timer manually(no front key on the timer can be used
for manual control). This switch can also be replaced with a control signal from computer or other control devices. The output
terminals (#8, 9 and 10) are from a "C form" internal relay. It is a dry switch that does not provide the power by itself. In this case,
the coffee grinder is powered by the same voltage as the power input .
2012.11
N
L
Coffee
Grinder
6
1
7
2
3
8
T1
9
4
10
5
WWW.AUBERINS.COM
Manual
T2
P3/4