3) Rear Connections

POWER CABLE

RED STRIPE
POWER CONNECTION:
POT CURVE TYPE:
PRECAUTIONS:
© 2017 Abstract Data Ltd.
-RED
10-16 pin Eurorack power connection
Jumper connection selects 1) Smooth or 2) Sharp Pot curves
Only connect the power cable to the power connection as shown.
DO NOT CONNECT THE POWER CABLE TO ANY OTHER PORT!
The ADE-51 uses the Doepfer standard for power connection and cable orientation.
The RED stripe on the supplied power cable connects to the NEGATIVE (-12V) rail
on the ADE-51 with the RED stripe facing DOWN. This is marked on the back of
the ADE-51 PCB as "– RED".
The ADE-51 has diode and polyfuse protection built in but an incorrectly connected
cable may still cause permanent damage to the module or the power supply.
The rear panel of the ADE-51 has exposed parts and connections. Please ensure
when handling the ADE-51 that the unit is held by the sides of the front panel or
the sides of the PCB (Printed Circuit Board).