CLEANING AND MAINTENANCE

Routine cleaning and maintenance is recommended

REPLACEMENT OF DISINFECTANT BOTTLE

• Use the key supplied to open the door
• Remove empty bottle from the rack
• Replace with new bottle
• Insert pump tube into the bottle
• Close the door
CLEANING AND MAINTENANCE OF CONTROL BOX
• Cut the power
• Remove any dust and dirt
• Do not rinse with running water
• Use a damp cloth and mild cleaning solution. Never use cleaning detergents with
an abrasive effect
CLEANING AND MAINTENANCE OF TAP/SENSOR
• Do not rinse with running water
• Use a damp cloth and mild cleaning solution. Never use cleaning detergents with
an abrasive effect
• Clean sensor for dust and dirt to prevent unintentional activation
12
TROUBLESHOOTING AND CORRECTIVE ACTIONS
SYMPTOM
POTENTIAL CAUSE
No disinfectant is
Low supply
delivered
Sensor window is dirty
Obstruction in front of the
sensor window
Damaged sensor
Tube disconnected from pump If the end of the tube is damaged,
Sensor cabling disconnected
from control box
Power supply has been
disconnected
AC/DC adapter not connected
The dispenser
Sensor window is dirty
activates
Obstruction in front of the
unintentionally
sensor window
Damaged sensor
CORRECTIVE ACTION
Refill the disinfectant bottle
Clean the sensor window
Remove the obstruction
Contact DAN DRYER for advice
please remove the damaged part. The
undamaged tube is to be mounted on
the nozzle exit of the pump
Check that the cable from the faucet
is installed correctly in the control box
Check that the cable from the adapter
or the external battery box is installed
correctly in the control box (see page
7)
Check that the AC/DC adapter is
plugged into the wall and is getting
power
Clean the sensor window
Remove the obstruction
Contact DAN DRYER for advice